SET HOME FAVOCITES

HeFei Vetus Electronic Technology Co., Ltd.

TDS-100H

TDS-100H Ultrasonic flowmeter with M2 Type Transducer digital flow meter

Linearity

0.5%

Repeatability

0.2%

Accuracy

±1% of reading at rates>0.6 ft/s. ±0.5% with on-site calibration

Response Time

0-999 seconds, user-configurable

Velocity

±0.03 ~ ±105 ft/s (±0.01 ~ ±30 m/s), bi-directional

Pipe Size

 (15 ~ 6,000mm)

Rate Units

Meter, Feet, Cubic Meter, Liter, Cubic Feet, USA Gallon, Imperial Gallon, Oil Barrel, USA Liquid Barrel, Imperial Liquid Barrel, Million USA Gallons. User configurable.

Totaliser

7-digit totals for net, positive and negative flow

Liquid Types

Virtually all liquids

Security

Setup lockout. Access code needed for unlocking

Display

4x16 English letters

Communication Interface

RS-232C, baud-rate: from 75 to 115,200 bps. Protocol made by the manufacturer. User protocols can be made on enquiry.

Transducers

Model M1 for standard, other 3 models for optional

Transducer Cable

Standard 2x30? (10m), optional 2x1,500? (500m)

Power Supply

3 AAA Ni-H built-in batteries. When fully charged it will last over 10 hours of operation.

90-230VAC for the charger

Data Logger

Built-in data logger can store over 2,000 lines of data

Manual Totalizer

7-digit press-key-to-go totalizer for calibration

Housing Material

ABS. Aluminum alloy protective case

Case Size

3.9"x2.6"x0.8" (100x66x20mm)

Handset Weight

1.2 lbs (514g) with batteries

Package include the below accessories:
1 x Ultrasonic Flowmeter
1 x Electro-acoustic Transducer Type M2 or S1
2 x 5M Connection Cable
2 x Fastening Chains
3 x AAA Batteries Ni-H
1 x Charger
1 x Conversion plug
1 x 5M Ruler
1 x Carring Case
1 x Empty plastic bottle (for loading gel)
1 x Instruction Manual (Chinese and English)